Alarms and Events - General Definition
In the following table you will find all kind of general alarm settings. The alarms/events are repeated every x minutes in case the alert is still on.
Email 60 means: 1 Email every 60 minutes
SMS 120 means: 1 SMS every 120 minutes
Report 60 means: 1 entry in the report every 60 minutes
SMS alerts are charge-able and not available in all countries. Please contact your provider.
A few alarms need special hardware-conditions or accessories like the CANBUS or the Garmin FMI Navigation System, they are optional of course.
Event | Description | Where to configure | E-mail x min. | SMS x min. | Report x min. |
Wrong Driver Registered Alarm | The identified driver is not on the list of assigned drivers iButton driver identification required | Asset Alert | 60 | 120 | 60 |
Speeding Alarm | Exceed speed, total speed or geofence-speed is exceeded | Asset Name & Alert | 5 | 30 | 1 |
Ignition On Alarm | Ignition is activated | Asset Alert | 1 | 5 | 1 |
Ignition Off Alarm | Ignition is de-activated | Asset Alert | 1 | 5 | 1 |
Ignition OFF & Movement | Tow alert: when speed is detected but ignition is 0 | Asset Alert & Hardware Setting | 5 | 10 | 5 |
SOS Alarm | Button that is connected to digital input is pressed | Asset Alert | 1 | 1 | 0 |
Strong Breaking Alarm | G Value Limit on device exceeded (only AT1 and AT5) | Asset Alert & Hardware Setting | 5 | 10 | 1 |
Restricted Usage Alarm | Ignition is started in the time window | Asset Alert | 30 | 60 | 30 |
Temp Sensor 1 Max. Temp Alarm | Requires temperature sensor probe and AT5 | Temp. probe | 10 | 20 | 2 |
Temp Sensor 1 Min.Temp Alarm | Requires temperature sensor probe and AT5 | Temp. probe | 10 | 20 | 2 |
Temp Sensor 2 Max. Temp Alarm | Requires temperature sensor probe and AT5 | Temp. probe | 10 | 20 | 2 |
Temp Sensor 2 Min.Temp Alarm | Requires temperature sensor probe and AT5 | Temp. probe | 10 | 20 | 2 |
Temp Sensor 2 Max. Temp Alarm | Requires temperature sensor probe and AT5 | Temp. probe | 10 | 20 | 2 |
Country Leaving Alarm | TeleAtlas Data shows new country code | Asset Name | 60 | 120 | 30 |
Geofence Staying Alarm | Positions inside an area must be triggered | Geofence | 30 | 60 | 5 |
Geofence Leaving Alarm | Exiting the area | Geofence | 2 | 2 | 2 |
Geofence Entering Alarm | Entering the area | Geofence | 2 | 2 | 2 |
Service Required Alarm | Odometer, operation hours or days are exceeded | Asset Service | 1000 | 1000 | 500 |
Potential Fuel Fraud Alarm | Based on Fuel Monitoring Device | Asset Alert | 1 | 5 | 1 |
Monthly Private KM Limit Alarm | Limit exceeded | Asset Alert | 10 | 10 | 2 |
Monthly KM Limit Alarm | Limit exceeded | Asset Alert | 30 | 30 | 2 |
CAN Bus Fuel level Alarm | Based on CANBUS % deviation | CANBUS Alert | 1 | 5 | 0 |
Battery disconnected alarm | Main power lost Only with Atrack devices | General | 10 | 10 | 2 |
Low Voltage (Battery) Alarm | External power is getting low Only with Atrack devices | General | 10 | 10 | 2 |
Strong Acceleration | Exceeding g value (only AT1, AT5) | Asset Alert & Hardware Setting | 1 | 5 | 0 |
Second Input ON | Digital input change | Asset Alert | 1 | 5 | 0 |
Second Input OFF | Digital input change | Asset Alert | 1 | 5 | 0 |
Third Input ON | Digital input change | Asset Alert | 1 | 5 | 0 |
Third Input OFF | Digital input change | Asset Alert | 1 | 5 | 0 |
Forth Input ON | Digital input change | Asset Alert | 1 | 5 | 0 |
Forth Input OFF | Digital input change | Asset Alert | 1 | 5 | 0 |
First Input On | Digital input change | Asset Alert | 1 | 1 | 0 |
First Input Off | Digital input change | Asset Alert | 1 | 5 | 0 |
The alert is triggered in different ways:
Functions and fields | Description |
Empty | No alert will be registered |
Report, View | Alarm in the event list and alarm report |
Alarm in the event list and alarm report and Email | |
Email, SMS (optional) | Alarm in the event list and alarm report and Email and SMS |
SMS (optional) | Alarm in the event list and alarm report and SMS |
Alarm Call (optional, Beta-Feature) | Alarm in the event list and alarm report and Email and SMS and Call The call will be triggered from a computer system, it always has the same number so we recommend that you save the number and assign it a priority ring tone on your phone |
Report, no view | Alarm not in the event list, only in alarm report |