3.8.36 GPS Fleet Sotware IOT Sensor Release

3.8.36 GPS Fleet Sotware IOT Sensor Release

Changes/Bug fixes

  • A white background was added to the asset text in the map to read it easier.
  • The new setting "Show as stopped time (min) changes the asset colour in the asset list from
  • In the Options>GUI1 you can add the temperature values of the ibutton temperature sensor 1, 2 or 3 to the logbook report. The start temperature (ST), end temperature (ET) and average temperature (AT) are shown.

  • There are 2 new speed filters to reduce alerts with lower speeds:
    • You can configure a minimu speed for the movement alert (e.g. 30 km/h) so that the movement alert is only triggered if the asset is moved without ignition AND speed above 30 km/h. This speed filter reduces alerts if devices record short movements (e.g. 1 or 2 km/h)
    • The driver alarm minimum speed is used to filter wrong driver alerts below 20 km/h. This is necessary if the trip starts before the driver can sign in using this driver identification.
  • The Digital Input report got a new counter coloumn that counts the number of events:

New Features for IOT Sensors

IOT Data View

The sensor raw data are shown in the IOT Data.

You can filter for single sensors or time ranges.

The IOT sensor data can be exported via Excel.

 

 

IOT Sensor list with map view

The sensor data is shown in the sensor list and in the map (linked with a Geofence, asset or gps lat / long position)

 

IOT Smartphone App view

You can check the current sensor data in the GPS Fleet Software Smartphone App.

   

 

New sensor configuration

  • If IOT is activated in the Options-menue, you can add new sensors.

  • New sensors have to be pre-configured by the provider.

Types of sensors

Please contact your provider for further details

FeatureDescription
Sensor KVA200KVA Sensor with mycro ampere
Sensor KVA200 MMKVA Sensor with millimeter
Sensor Sonicultrasonic sensor
Sensor TEK750n.n.

 

 

IOT Sensor Configuration

 

 

FeatureDescription
Sensor NameName in the software and in the map
Sensor SerialSerial number
IMEIUnique IMEI number of the sensor
Sensor TypeSensor type that is linked with the IMEI
ImageIcon to display the sensor
Report groupfor future use
Msisdnused mobile phone sim number
Passwordfor future use
No new data from box sincefor future use
Line colorAnzeige der Sensorfarbe in der Landkarte
Disable in reportsfor future use
Out of servicefor future use
Not show in Mapsfor future use
Installed at customer (Geofence)Sensor is located at the Geofence location in the map
Installed at assetSensor is located at the asset's location in the map
Installed at Lat / LongSensor is located at the GPS lat and long location in the map
Location infoFree text
Materialfor future use
Alarm E-Mail

You can several email recipients for alerts (, separated)

The alerts are sent daily, not in real-time, at the moment.

Alarm SM/Call

for future use

The alerts are sent daily, not in real-time, at the moment.

Salzmanager PlantID

ID for forwarding data to the Salzmanage Program

http://www.salzmanager.net/extranet/sendlevels/

Salzmanager Password

Passwort for forwarding data to the Salzmanage Program

http://www.salzmanager.net/extranet/sendlevels/

  

 

Sensor Details

 

FeatureDescription
h in cmHeight of the tank
x in cmDistance between tank bottom and sensor
x offset in cmHow many cm does the sensor stick out the full tank (highest level)?
Min. Alarm

Type of alert (report, email, sms...)

Beta-Test-Feature

for future use

Min. Value (%)Lower values will trigger an alert
Min. Restriction

Alert only within the restricted times

Beta-Test-Feature

for future use

Max. Alarm

Type of alert (report, email, sms...)

Beta-Test-Feature

for future use

Max. Wert (%)Higher values will trigger an alert
Max. Restriction

Alert only within the restricted times

Beta-Test-Feature

for future use

Value 1 Liter (l)

Max. Liter

How many liters does the full tank contain (100%)
Tank shapeRectangle Fuel tank oder round (see image below)

Value 2 tons / kgs

 

Which weight does the full tank have ?
Unitunit for weight
DimensionsPre-configured fuel tanks
SalzmanagerCheckbox YES for data forwarding

 

Further fixes:

  • Canbus Fuel Level Alarm was improved
  • Asset configuration > Logbook: the feature "Delete short waiting times" was improved, short stops will be ignored in the logbook report. This feature has no effect on the rawdata.
  • Asset configuration > Logbook:the feature "" was added to insert a stop in the logbook even if a device is sending short movements (less than 10 meter) during stops with ignition on. This feature has no effect on the rawdata.
  • CANBUS data from FMS and LVCAN adapter have been improved in the history raw data excel